What cold nights do to a heat pump here
Your winters are the whole question. Heat runs eight months a year in Erie County, October through May, and the overnight low averages 23°F in December, January and February. That number sits below both marks that matter for a heat pump: below 40°F it stops putting out its full rated heat, and below about 35°F it often leans on backup heat to make up the difference. Your average winter night is below both.
About 115 nights a year here drop to freezing or below, roughly half the nights across the whole heating season. On most of those nights a standard heat pump is working below its rated capacity. Only about 4 nights a year reach 0°F, so the deep cold is rare, but the mild freeze that cuts into a heat pump's output is not rare here. It is most of the winter.
That does not rule out a heat pump. The ENERGY STAR Cold Climate models are built and tested for exactly this: to still make 1.75 units of heat for every unit of electricity at 5°F, and to hold onto at least 70 percent of their warm-weather capacity at that temperature. Field tests of cold climate models in real homes back this up. Backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump and a cold climate heat pump are not the same purchase in a county like this one.