What winter here actually asks of a heat pump
Your furnace, or your heat pump, has to answer for seven months of the year here, October through April. That is the longer of your two seasons by a wide margin, so this decision is mostly a heating decision, not a cooling one.
The average overnight low across December, January and February is 24 degrees. That number matters because a standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. Your average winter night is below both marks, and so is every single one of the roughly 115 nights a year that drop to freezing or lower. Over half the nights you run heat fall into that stretch.
That does not mean the heat pump is struggling constantly. It means it is working harder, and sometimes leaning on backup heat, for a solid chunk of an average winter here, not just on the rare brutal night.
The really cold nights, the ones at 0°F or below, are rare here, about 3 a year. A modern cold climate heat pump is built and tested for exactly that range. To earn the ENERGY STAR Cold Climate label, it has to still produce 1.75 units of heat per unit of electricity at 5°F and hold onto at least 70 percent of its 47°F capacity at that same temperature. Field tests of these units in occupied homes back that up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F.
So the cold itself is not the obstacle it sounds like. A standard heat pump will feel the 24-degree nights that make up most of your winter. A cold climate one is built for the handful of nights that go lower still.