Electricity here runs 16.50 cents a kilowatt-hour
Butler County pays more for power than most US counties. A heat pump runs on electricity for both heating and cooling, so that rate applies to the system every month of the year, not just in summer.
Takes about a minute. No obligation.
Butler County pays more for power than most US counties. A heat pump runs on electricity for both heating and cooling, so that rate applies to the system every month of the year, not just in summer.
Two heat pumps can use the same electricity at very different rates of output. At 16.50 cents a kilowatt-hour, the difference between an efficient unit and a weak one shows up on every bill it sends, all year.

NOAA nClimDiv, 1991–2020 normals
Gas heats most homes in Butler County.
A heat pump taking over for a gas furnace is going into new territory here, not familiar ground.



Butler County falls under zone 4A in the 2021 energy code, a mixed climate that takes real work from both sides of the system. Any split-system heat pump installed here, if built from 2023 onward, has to clear a federal floor: at least 14.3 Btu of heat moved per watt-hour of electricity over the summer, and at least 7.5 Btu per watt-hour over the winter. That floor narrows the field before you even start comparing units. It also means the baseline here is already higher than it used to be, so an older model pulled from a warehouse shelf may not qualify for installation at all.
Picking the unit is only half of it. Installed and set up right for this house, that efficiency is what shows up on the bill every month it runs, not just the month it goes in.
Find a contractor
The unit is one line item. The rest of the cost is everything that gets it moved into the house correctly. Sizing takes real work, a contractor has to calculate the heat loss and heat gain for the house room by room, not just match whatever size is already there. Go too big and the system short cycles, turning on and off before it ever runs long enough to settle the air. Go too small and it runs constantly, straining to keep up on the coldest and hottest days. Ductwork matters just as much. A heat pump moves a different volume of air than a furnace was built around, and ducts that are too narrow or leaky undo a lot of the equipment's efficiency before the air ever reaches a room. The refrigerant lines have to be the right length and charged to the exact amount the manufacturer specifies, not just topped off by feel. A heat pump also needs a way to handle defrost cycles in winter, melting the frost that builds on the outdoor coil, and that setup has to be right or the system loses heat it can't afford to lose. None of this shows up by looking at the unit sitting outside. It shows up in how long the system lasts and how much it costs to run every month after the installer leaves.
A heat pump carries a cooling rating and a separate heating rating. The cooling number tells you how it performs pulling heat out of the house. The heating number tells you how it performs putting heat back in, which is a different job for the same equipment. A unit can be strong on one side and only average on the other, so the single number on a spec sheet or a sticker doesn't tell the whole story by itself.
That number is measured in a lab, with the refrigerant charge exact and the airflow set the way the manufacturer intended. The unit in the house only gets close to that number when it's installed to match those conditions. Charge that's off, airflow that's restricted, or a coil that's dirty all pull real performance below what the rating promised, even though the equipment itself never changed.
Two systems can carry the same rating and still be different machines underneath. Ask what the compressor is, not just the brand on the cabinet, because the compressor is what wears and what moves the heat. Ask how it handles low outdoor temperatures, since a heat pump works by pulling heat from outside air, and some compressors hold their output as it gets cold while others drop off hard and lean on backup heat strip instead. Ask whether the system is single-stage, two-stage, or variable-speed. A single-stage unit runs at full blast or not at all. A variable-speed unit adjusts its output to match what the house needs at that moment, which means steadier temperatures and less wear from constant starting and stopping. Ask what the sound rating is too, since the outdoor unit runs through the winter as well as the summer, right outside a window or a patio.
Install day starts outside with the slab or pad going in level, because a unit that sits tilted strains the compressor over time. The old equipment comes out, and if the ductwork is being reused the installer checks it for leaks and size before anything new connects to it. Refrigerant lines get run, pressure tested, and pulled into a vacuum to clear out moisture and air, since either one left behind will break down the system from the inside. The line set gets charged to the exact weight the manufacturer specifies, not judged by feel or by how cold the lines feel to the hand. Indoors, the air handler or coil goes in, the electrical hookup gets tied in and tested, and the thermostat gets wired and set up to actually run the system's stages instead of just turning it on and off. Before the crew leaves, the system should run through a full cycle, heating and cooling both, while someone checks the temperatures coming off the vents against what the equipment is supposed to deliver.