What cold does to a heat pump here
Your winters decide this more than your wallet does. The overnight low here averages 25°F across December, January and February, and that's below the two marks that matter for a heat pump. Below 40°F a standard heat pump's output falls short of its rating. Below about 35°F it often needs backup heat to keep up. Your average winter night is below both marks, not close to them.
This isn't a rare cold snap. About 105 nights a year here drop to freezing or below, and every one of those nights is below the 35°F and 40°F marks. Only about 2 nights a year reach 0°F. The real story of a Hamilton County winter is the ordinary night in the mid-20s, not the rare hard freeze, and a standard heat pump is already short of its rated output on that ordinary night. A furnace doesn't work this way. It burns gas and makes its full rated heat whether it's 40°F outside or 10°F.
There's a real fix for this, and it matters which heat pump you'd actually be buying. One built to carry the ENERGY STAR Cold Climate label has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. A two-winter field test of prototype cold-climate models in occupied homes backed this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. A federal-minimum heat pump and a cold-climate one are not the same purchase here.