What the cold does to a heat pump here
Your winters are the whole question. The heat runs seven months a year in Scioto County, and the overnight low averages 26 degrees in December, January and February. That number matters because a standard heat pump starts losing ground below 40 degrees and often needs backup heat below about 35. Twenty-six is under both marks, and it's not the cold snap, it's the average night.
About 115 nights a year here drop to freezing or below, over half the nights in the heating season. Every one of those nights sits below both the 40 degree and the 35 degree marks, so on more than half the winter a standard heat pump is working below its rated output and likely leaning on backup heat to keep up. The deep cold, nights at 0 degrees or below, only happens about twice a year. So the argument against a heat pump here isn't about rare extreme cold. It's about ordinary winter nights in the 20s and 30s, which is most of them.
A cold-climate heat pump is built for exactly this. To earn the ENERGY STAR Cold Climate label, it has to deliver real heat at 5 degrees outside and hold onto most of its 47 degree capacity at that temperature, tested by someone other than the manufacturer. A two-winter field test of these units in actual homes found backup heat only filled in a small share of the output between 0 and 35 degrees, and running on backup alone was rare even above 0. If you're buying a heat pump for this county, that's the version built for your winters, not the standard one.