What the cold does to a heat pump here
Your winter nights average 25°F in Washington County. A standard heat pump starts losing ground before it even gets that cold. Below 40°F its output falls short of its rating. Below about 35°F it often needs backup heat to make up the difference. Your average night sits past both marks, and so does every one of the roughly 110 nights a year that drop to freezing or below.
That doesn't mean the heat pump quits on you. Only about 2 nights a year here reach 0°F, a small slice of those 110 freezing nights. Field tests of cold-climate heat pumps running through real winters found backup heat carried only a small share of the load even between 0°F and 35°F, and running on backup alone was rare above 0°F. If you buy a heat pump here, buy one built for cold climates. A standard model built to the federal minimum will struggle on more nights than it should.
The ENERGY STAR Cold Climate mark means something specific: the heat pump still makes at least 1.75 units of heat per unit of electricity at 5°F, and still holds at least 70 percent of its 47°F capacity at that same temperature, checked by outside testing. That's the kind of machine built for a winter like this one, not the federal-minimum machine the $2.13 running cost above was priced from.