What the cold actually does here
Your winter low here averages 23°F, and that number matters more than any spec sheet. A standard heat pump starts falling short of its rated heat below 40°F, and below about 35°F it usually needs backup heat to keep up. Your average night is below both marks. About 115 nights a year here drop to freezing or below, roughly half the nights across the eight months you run heat, and every one of those nights is cold enough to push a standard heat pump onto its backup.
That backup heat is almost always electric resistance heat, the same expensive way a space heater works. It is why the running cost printed above for a heat pump, $2.13 per 100,000 Btu, is likely optimistic for this county. That figure comes from the heat pump's seasonal rating alone, with nothing added for the backup heat it will actually lean on here. A gas furnace has no such gap. It is rated to make its heat at whatever temperature it is outside, and it does, which is part of why it already costs less to run on paper, $1.61 against $2.13 per 100,000 Btu.
None of this rules out a heat pump. It rules out a standard one. If you are set on a heat pump in this county, the one worth paying for carries the ENERGY STAR Cold Climate mark, which requires it to still make 1.75 units of heat per unit of electricity at 5°F and hold on to most of its capacity at that temperature, tested by someone other than the manufacturer. Field tests of these cold climate units in occupied homes back this up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. Your 4 nights a year at 0°F or below are the only nights that come close to testing one.