What winter here does to a heat pump
Your furnace or heat pump has to work from October through May here, eight months, longer than any other job the system does. That is the fact that should drive the decision, not the sticker on the equipment.
A standard heat pump starts losing ground below 40°F and often needs backup heat below about 35°F. Delaware County's overnight low averages 23°F across December, January and February, so a normal night here sits below both marks. About 110 nights a year drop to freezing or below, and on every one of them a standard heat pump is working outside the range it was built for.
That does not mean the heat pump quits. Only about 3 nights a year reach 0°F, and a two-winter field test of cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. If you buy a heat pump here, buy one rated for cold climates, not the minimum-efficiency model the running-cost figures above are based on. An ENERGY STAR Cold Climate unit has to prove it still makes 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. A standard heat pump has no such requirement and will lean on backup heat far more on your coldest nights.