Your heat runs eight months a year here, October through May, and the overnight low averages 22°F across December, January and February. That number matters more than it sounds like it should. A standard heat pump starts losing heating capacity below 40°F, and below about 35°F it usually needs backup heat to make up the difference. Your average winter night is below both marks.
About 120 nights a year here drop to freezing or below, roughly half the nights across the whole heating season. On every one of those nights, a standard heat pump is working below the point where it puts out its full rated heat. That is not a rare cold snap. That is most of a typical winter.
The other end of the scale is less of a problem than people expect. Only about 4 nights a year reach 0°F, and newer cold-climate heat pumps are built for exactly that range. In a two-winter field test of prototype cold-climate models running in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the units ran on backup heat alone only rarely, even near 0°F. A heat pump rated for cold climates, carrying the ENERGY STAR Cold Climate mark, has to prove it still makes 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. That is the spec to look for if you want a heat pump here, not the federal minimum unit the running-cost figures above assume.