Furnace Maintenance in Kent, OH

Tell us about the job

Takes about a minute. No obligation.

Tune-up, service, or cleaningFurnace or heatingPortage County, OH
Step 1 of 2

What ZIP code is the job in?

Furnaces in Kent sit idle most of the year, then have to run hard starting in October. Get one checked in September. That gives a technician time to catch a weak igniter or a dirty flame sensor before the first cold night. Wait until October and it turns into a fix instead of a check, probably on a day the heat was already needed. Furnaces here run about eight months straight, October through May. There's no slow ramp up. It goes from off to on and stays on.

Heat here lasts eight months. That's one long stretch of the system running, not a few short bursts here and there.

Get the furnace checked once before October. After that, it can be left alone until spring.

One check before October covers the whole stretch to May

Heat runs October through May
Winter nights average 21°F
Climate zone 5A

Gas heats 63.7% of homes in Portage County, more than any other fuel. So most furnaces in Kent are gas furnaces. That means a burner, a flue, and a set of safety controls, not just a blower and a filter. The burner has to light clean every time and burn clean the whole run. The flue has to carry exhaust out of the house, not back into it. A maintenance check on a gas furnace covers both, along with the flame sensor and igniter. Some homes here heat with oil instead. Those need the same look at the burner and venting before the heat gets asked to run.

One check a year covers it

Portage County gets its share of wind, hail and winter storms. That doesn't change what a furnace needs. One check a year still covers it, the burner, the flue and the flame sensor. That's enough to carry the system through its long run.

Find a contractor
A man in a gray shirt and tan work pants, seen from behind, climbs porch steps toward a dark blue front door while carrying a canvas tool bag, with a potted shrub to the right.
A gray residential gas furnace installed in an unfinished basement, surrounded by ductwork, a metal flue pipe, and a gas supply line.

What a tune-up catches before you do

A furnace builds up problems all year without anyone noticing. Dust settles on the blower wheel and flattens the blades, so the motor has to work harder to push the same air. The flame sensor picks up a film from normal use until it can't tell the burner is lit anymore, and the system shuts itself off, usually on the coldest night yet. Pressure switches and the draft inducer wear out in ways nobody hears from another room. A tech pulls the burner assembly and checks the flame itself. Color and shape can point to a cracked heat exchanger before it turns into a safety problem instead of a repair. None of this shows up as a noise or a smell first. It just shows up as a furnace that quits.

A short cycle is the first sign

A furnace that turns on, runs a few minutes, then shuts off and starts again again is telling you something. Usually it's a flame sensor losing its signal, or a flue restriction tripping a pressure switch. That's not the kind of thing that waits to get worse on its own.

A loud bang on startup isn't normal

When gas builds up in the burner before it lights, then catches all at once, that makes a bang instead of a quiet whoosh. That means the burner isn't lighting clean. A burner that isn't lighting clean now isn't going to start lighting clean later.

Change the filter yourself. A dirty filter chokes the blower and that strain is what grinds down a motor over a few winters. Check it monthly during the run and hold it up to a light. If you can't see light through it, it's done. Keep the area around the furnace clear too, so it can pull in the air it needs to burn clean. Past that, leave it alone. The burner, the flue and the flame sensor aren't something to open up yourself, and that's what the yearly check is for.

A proper tune-up starts before the burner gets touched. Gas pressure gets checked at the manifold first, because too high or too low changes how clean the burner lights and burns. The igniter gets tested for resistance, not just a glance. One that still glows can still be too weak to light the burner reliably. The heat exchanger gets checked for cracks, usually with a camera or a mirror, because it sits behind the burner where nobody can see it without taking the furnace apart. Belts aren't part of this. Most furnace motors drive the blower directly. But the blower wheel and motor still get checked for dust buildup, since that's what makes a motor strain. Last comes a static pressure reading across the whole system. That catches a restriction in the ductwork, something no amount of burner work will fix.