Eight months of work
A furnace in Bowling Green runs from October through May. Overnight lows average 22°F through December, January and February. That's a long stretch for one machine to carry a home through.

Takes about a minute. No obligation.
A furnace in Bowling Green runs from October through May. Overnight lows average 22°F through December, January and February. That's a long stretch for one machine to carry a home through.
Get it checked before October. That catches a weak igniter or a dirty flame sensor while it's still an easy fix. Wait, and it turns into a no-heat call on a January night.
Furnaces start working hard as soon as October hits.
Get it checked in September. That way nothing's left to chance on the first cold night.



Most homes in Wood County heat with utility gas. That's 64.6% of them. Electricity is a distant second at 23.0%, and bottled or LP gas covers another 9.3%. A gas furnace has a burner, a venting system, and safety controls that an electric furnace doesn't have. A maintenance visit checks that the burner lights clean. It checks that the flue is drafting right. It checks that the sensors meant to shut things down if something goes wrong can actually do it. A filter change doesn't touch any of that.
A gas furnace needs a check every year. Doesn't matter if it's a mild winter or a hard one. Natural gas cost Ohio homes $12.89 per million Btu last year. A burner that's not lighting clean wastes part of every bill it causes. One visit catches that before the cold settles in for good.
Find a contractor
Skip the yearly check and the furnace won't fail right away. It just keeps running worse. Dust builds up on the flame sensor until it can't read the flame right, so the furnace shuts off mid-cycle and relights, over and over. The burner goes longer between cleanings and starts lighting dirty, so more soot heads up the flue instead of heat heading into the house. A blower wheel caked with dust moves less air than it should, so the heat exchanger runs hotter than it was built for. That's what shortens its life. None of this shows up as a no-heat call the first year, or even the second. It shows up as a furnace that runs worse every winter and dies younger than it should have.
A heat exchanger can split along a seam and still pass heat most days. The crack only shows up under a pressure test or a combustion test. Those are part of a tune-up. There's no way to see it or smell it from the next room.
A blower motor pulling more amps than it should is working harder to do the same job. Usually that means the bearings are wearing out. Catch it at a tune-up, and it's a motor replaced on a schedule. Miss it, and it's a motor that seizes on a night the furnace can't be down.
A few things are worth watching for before the check even happens. A burner flame that's yellow or flickering instead of steady blue is burning dirty. Mention that when the furnace gets looked at. A furnace that short-cycles, running a few minutes then shutting off before the house warms up, usually means the flame sensor isn't reading the flame right. A burning or dusty smell the first few times the furnace runs each fall is normal, that's just dust in the ducts burning off. A smell that sticks around past the first few days is not normal. Rooms that used to heat evenly and now run cold in the corners mean the blower isn't moving air like it used to. None of this means the furnace is about to quit. But each one is exactly what a tune-up is supposed to catch, before the cold puts more demand on the furnace than it can handle.
A tune-up starts at the thermostat and works through the whole system in order. First the burner flame, looking for a steady blue flame, not one that's yellow or lifting off the burner. Then the flame sensor, cleaned or tested so it reads the flame right instead of shutting the furnace down mid-cycle. The heat exchanger gets checked for cracks along the seams, usually with a combustion analyzer, since a crack doesn't always show up to the eye. The blower motor and wheel get checked for amp draw and cleaned if dust has built up on the blades. A dirty wheel moves less air no matter how strong the motor is. The flue and venting get checked too, to make sure exhaust is actually leaving the house instead of backing up. And every safety control gets tested on purpose, tripped and watched, to make sure it still shuts the furnace down the way it's supposed to when something goes wrong.