What winter here does to a heat pump
Your furnace question here is really a cold question. The overnight low averages 23°F across December, January and February, and that sits below both marks that matter for a heat pump. Below 40°F a standard heat pump puts out less heat than its rating. Below about 35°F it often needs backup heat to make up the difference. Lake County's average winter night is below both, and every one of the roughly 115 nights a year that drop to freezing or below is too.
That doesn't mean a heat pump quits. It means it leans on backup more often than it would in a milder county. The nights that really test it, the ones at 0°F or below, number about 3 a year here, a small part of the season. The harder problem is the ordinary cold. Half the nights in the 8 month heating season sit at or below freezing, and that's where a standard heat pump spends a lot of its time working below its rated output.
A cold climate heat pump is built for exactly this. To earn that designation it has to deliver at least 1.75 units of heat for every unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that same temperature, with both numbers checked by outside testing. Field tests back this up. Over two winters of testing prototype cold climate units in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump in Lake County will ask its backup heat to work. A cold climate one mostly won't.