What winter here does to a heat pump
Your furnace or heat pump runs seven months a year in Warren County, October through April. The overnight low averages 25°F across December, January and February, and it drops to freezing or below on about 115 nights a year, over half the nights heat runs at all. A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F its heat output falls short of what it is rated for, and below about 35°F it often needs a backup heat source to keep up. Both marks sit above 25°F, and every one of those 115 freezing nights falls below both. A furnace does not have this problem. It burns gas and makes the same heat on demand no matter how cold it is outside.
The cold here does not stay extreme. Only about 3 nights a year reach 0°F or below, a small share of the 115 freezing nights. A heat pump built to carry the ENERGY STAR Cold Climate designation is tested to still make at least 1.75 units of heat for every unit of electricity at 5°F, and to hold onto most of its 47°F capacity at that temperature, colder than almost anything this county sees. A two-winter field test of prototype cold-climate heat pumps in occupied homes backed this up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the stretch where a standard heat pump struggles, below 35°F, is most of this county's winter, but a cold-climate model is built for that stretch, and the nights that would actually test its limit are rare here.